63
c. Proximity Switch Replacement
1) Discontinue electrical power to the dryer.
2) Remove the two (2) 1/4-20 x 1/2” bolts from
each side of the middle guard and then
remove the guard.
3) Remove the three (3) 1/4-20 x 3/4” bolts from
the bottom guard.
Take notice of the depth of the proximity
switch.
4) Unscrew and remove the nut that is on the
bottom of the proximity switch.
5) Install new proximity switch.
6) Set gap between the proximity switch and
the magnet at 3/16” +/- 1/32” (4.7625 mm
+/- 0.79248 mm).
7) Reinstall middle guard and secure with the
bolts removed in Step #2.
8) Reestablish electrical power to the dryer.
d. Right Load Door Glass (Window) Replacement
1) Remove ALL of the old silicone from around
the door glass.
2) Clean glass door opening (with alcohol) to
remove ALL foreign residue.
3) Carefully clean new door glass with alcohol
prior to installation.
4) Apply a bead of silicone (ADC Part No.
170730) to the outer perimeter of the door
glass opening.
Carefully insert new door glass within door
glass opening.
5) Allow a full 72 hours for the silicone to cure.
6) Trim excess silicone (with razor blade) after
cure time.