62
b. Cable Cylinder Replacement and/or Removal
1) Discontinue electrical power to the dryer.
2) Remove the two (2) 1/4-20 x 1/2” bolts from each side of the middle guard.
Remove the middle guard.
3) Disconnect the cables in the top of the electrical panel.
4) Remove the hardware from the top guard.
Remove the top guard.
5) Remove the two (2) #8-32 x 3/4” screws on each door that attach the cable cylinder to the door.
6) Remove the four (4) #8-32 x 2-1/2” screws that hold each cable cylinder.
7) Remove the flow control valve...
a) The flow control valve has a quick disconnect on the poly-flo tubing side...
Push the tubing in while holding in then pull the tubing out.
8) To install new cable cylinder(s) or reinstall cable cylinder(s), reverse above procedure (Step #7 thru
Step #1).