47
c. 3 HP (2.24 kw) Control Relay Replacement
WARNING: THE SPRINKLER CIRCUIT HAS A SEPARATE POWER SUPPLY (than the power
supply for the dryer). DISCONNECT AND LOCKOUT BOTH POWER
SUPPLIES BEFORE SERVICING THE DRYER.
1) Mark and identify the wires that will be removed for proper reinstallation.
2) Press down on the control relay and lift the bottom out and up to remove from the din rail.
3) Remove the wires.
4) Replace the faulty control relay.
5) Replace the wires removed from Step #3.
NOTE: Make sure wires are properly reinstalled using identifying markings from Step #1.