of 81
 
Pin Configurations and Assignments 3
Agilent U2802A 31-Channel Thermocouple Input User’s Guide 43
Connector J60
1. Refer to the U2300A Series USB Multifunction Data Acquisition Devices User’s Guide for
connectivity
Pin Pin name Description
1 COUNT302_CLK Directly connected to DAQ
1
2 COUNT302_GATE Directly connected to DAQ
1
3 COUNT302_UPDOWN Directly connected to DAQ
1
4 COUNT302_OUT Directly connected to DAQ
1
5 EXTD_AI_TRIG Directly connected to DAQ
1
6 EXT_TIMEBASE Directly connected to DAQ
1
7 GND Module Ground
8 AO_GND Directly connected to DAQ
1
9 AO_GND Directly connected to DAQ
1
10 GND Module Ground
11 GND Module Ground
12 GND Module Ground
13 COUNT301_CLK Directly connected to DAQ
1
14 COUNT301_GATE Directly connected to DAQ
1
15 COUNT301_UPDOWN Directly connected to DAQ
1
16 COUNT301_OUT Directly connected to DAQ
1
17 EXTD_AO_TRIG Directly connected to DAQ
1
18 GND Module Ground
19 AO201 Directly connected to DAQ
1
20 AO202 Directly connected to DAQ
1
21 AO_EXT_REF Directly connected to DAQ
1
22 EXTA_TRIG Directly connected to DAQ
1
23 GND Module Ground
24 GND Module Ground
U2802A_UG.book Page 43 Tuesday, January 8, 2008 10:24 AM