F. PROGRAM LOCATION 03 (PL03)
HI Temp
Location to be viewed/changed.
Press “Perm Press” key.
Display will read “HI°F,” “HI Temp” key
status for 3-seconds and then the actual
temperature programmed. If no changes,
press “Perm Press” key otherwise press
“HI” or “LO” keys and then “Perm Press”
key.
Temperature Increase
Temperature Decrease
Summary: HI Temp is programmable from a minimum of 100° F to a maximum of 190° F in ten-degree increments
or from a minimum of 38° C to a maximum of 88° C in five-degree increments.
For the AD-26 and AD-295 any three (3) of the selections (HI/LO/PP) are programmable from a
minimum of 100° F to a maximum of 170° F in ten-degree increments or from a minimum of 38° C to
a maximum of 77° C in five-degree increments.
For the AD-540 and WDA-540 any three (3) of the selections (HI/LO/PP) are programmable from
a minimum of 100° F to a maximum of 160° F in ten-degree increments or from a minimum of 38° C
to a maximum of 71° C in five-degree increments.
PL03
HI°F
Automatically goes into PL04
Program without PL04 Display
Mode
Perm Press
180F HI Temp
Perm Press
LO Temp
Refer to
Section V
for instructions
on entering program locations.
(Wait 3-Seconds)
Continued on next page