30 American Dryer Corp. 113202-10
Typical Water Supply
OPTIONAL MANUAL BYPASS
Provisions are made in the dryer’s fire suppression system for the installation of an optional manual bypass.
Depending on the model dryer, the connections for the manual bypass are made at the “T” or “three way” fitting
located in the outlet supply side of the water solenoid valve. The use and connections of this manual bypass are
at the option or discretion of the owner.
The water connection for the manual bypass is made to the “T” or “three way” fitting, which has a 3/8” F.P.T.
and a coupling must be used to provide the minimum 1/2” supply (feed) line.
If the rear area of the dryer, or the water supply is located in an area where it will be exposed to cold/freezing
temperatures, provisions must be made to protect these water lines from freezing.
WARNING: If the water in the supply line or water solenoid valve freezes, the fire suppression system
will be INOPERATIVE!!