1. Set the normal process temperature setpoint. The material saver setpoints are
set on the Overdry Protect Setup screen.
2. Set the deviation limits for process temperature alarms. Also set the standby
time to allow the drying temperature to rise to the set value at system startup.
3. Set the process ID for the hopper. This can be a press ID, product name, or
any other value that makes sense. Also, the hopper volume and heater KW are
set. These values are used in throughput and KWH calculations.
4. Press the material name to call up the Material Select screen described below.
Selecting a new material / recipe when the system is idle will automatically
change the drying temperature, setback temperature, residence time, and
density. If the dryer process is running, selecting a new material has no effect
on current settings.
5. Press the Autotune button to call up the Process Autotune screen described
below.
Material Select Screen
Use the Material Select screen to recall the material / recipe to use. Pressing the “Load” button
will make the highlighted recipe current and return to the Hopper Setup screen. Pressing the
“Setup” button will call up the Material Setup screen described below.