0

Out of 0 Ratings

Owner's of the NordicTrack Fitness Electronics Workout TV Console gave it a score of 0 out of 5. Here's how the scores stacked up:
  • Reliability

    0 out of 5
  • Durability

    0 out of 5
  • Maintenance

    0 out of 5
  • Performance

    0 out of 5
  • Ease of Use

    0 out of 5
of 12
 
4
Mount an antenna discharge unit
as close as possible to where the
lead-in enters the facility.
Use a jumper wire not smaller than
No. 6 AWG (13.3mm
2
) copper or
the equivalent when a separate
antenna-grounding electrode is
used. See NEC Section 810-21 (j).
Note to CATV system installer: This
reminder is provided to call the CATV
system installer’s attention to Article
820-40 of the NEC that provides guide-
lines for proper grounding and, in par-
ticular, specifies that the cable ground
shall be connected to the grounding
system of the building, as close to the
point of cable entry as practical.
WARNING: Before beginning this or any exercise program, consult
your physician. This is especially important for persons over the age of 35 or per-
sons with pre-existing health problems. Read all instructions before using.
FreeMotion Fitness assumes no responsibility for personal injury or property dam-
age sustained by or through the use of this product.
SAVE THESE INSTRUCTIONS
Power Lines
Ground
Clamps
Ground
Clamps
Ground
Clamp
Bonding
Jumper
Standoff
Insulators
Antenna
Lead-in Wire
Ground Wire
Ground
Wire
Antenna
Discharge Unit
To External Antenna
Terminal of Equipment
Mast
Service
Entrance
Equipment
Power Service Grounding
Electrode System (e.g.
Interior Metal Water Pipe)
Service
Entrance
Conductors
Optional Antenna Grounding Electrode Driven
8 Feet (2.44 m) Into The Earth (If Required By
Local Codes). See NEC Section 810–21 (f).