0

Out of 0 Ratings

Owner's of the Aprilaire Air Cleaner Aprilaire Air Cleaner gave it a score of 0 out of 5. Here's how the scores stacked up:
  • Reliability

    0 out of 5
  • Durability

    0 out of 5
  • Maintenance

    0 out of 5
  • Performance

    0 out of 5
  • Ease of Use

    0 out of 5
of 4
 
Media Air Cleaners
Installation Instructions
1. High voltage may cause serious
injury from electrical shock.
Disconnect power to the
furnace/air handler before
starting installation.
2. Sharp edges may cause injury
from cuts. Use care when cutting
and handling sheet metal.
WARNING
1. To prevent component failure, do not install the air cleaner on the warm
air supply or in an area where the temperature may exceed 140°F. This
may include areas above heat exchangers in downflow furnaces or above
exhaust flues in lowboy furnace cold air returns.
2. Installation must be done by a qualified heating and air conditioning
professional. Read instructions thoroughly before beginning installation.
3. Do not install air cleaner downstream of a UV light. UV lamps will cause
degradation of the filtering media.
CAUTION
SPECIFICATIONS
Airflow Capacity: up to 2000 CFM maximum
Replacement Media:
1210, 2210, 3210: Model 210 or 213 with SelfSeal
1310, 2310, 3310: Model 310 or 313 with SelfSeal
1410, 2410, 3410: Model 410 or 413 with SelfSeal
Max. Equipment Weight:
Cabinet will support 400 lb. static load
Air Cleaner Operating Environment:
Temperature: 0°F – 140°F
Humidity: 0-90% non-condensing
DIMENSIONS
TABLE 1 – Dimensions (inches)
Model A B C D E F G H
1210, 2210, 3210
19-3/4 25-3/8 21-3/16 6-3/4 27-3/8 21-3/16 19-3/4 22-1/16
1310, 2310, 3310
18-1/16 20-1/16 15-7/8 6-3/4 22-1/16 15-7/8 18-1/16 20-3/8
1410, 2410, 3410
15-7/16 28-1/16 23-7/8 6-3/4 30-1/16 23-7/8 15-7/16 17-3/4
A
B
without door
C
D
E
with door
F
G H
90-1333