3.0

Out of 1 Ratings

Owner's of the ACS Clothes Dryer ACS Clothes Dryer gave it a score of 3.0 out of 5. Here's how the scores stacked up:
  • Reliability

    0 out of 5
  • Durability

    4.0 out of 5
  • Maintenance

    3.0 out of 5
  • Performance

    4.0 out of 5
  • Ease of Use

    4.0 out of 5
of 59
 
350-2100 cfm Dryers Chapter 6: Maintenance 43 of 58
Display
Characters
Sensor Type Switch
Position
Temp
Range
°C °F
Thermocouple Type R 0 0 - 1,700 0 - 3,000
Thermocouple Type S 1 0 - 1,700 0 - 3,000
Thermocouple Type K 2 -200 to
1,300
-300 to
2,300
Thermocouple Type J 3 -100 to
900
-100 to
1,600
Thermocouple Type T 4 -200 to
400
-300 to
700
Thermocouple Type E 5 0 to 600 0 to 1,100
Platinum RTD (JIS
1981)
6 -99.9 to
450.0
-99.9 to
800.0
Platinum RTD (DIN) 7 -99.9 to
450.0
-99.9 to
800.0
Not Used 8
Not Used 9
9. Set both transmission output selector DIP switches OFF. They are marked SW207 (TRANSFER)
and are on the right circuit board on controls equipped with optional communications. See the
Communications Manual [part number A0535959].
123456
ON
10. The function selector DIP switch [SW201 (FUNCTION)] selects 6 control modes. It is on the right
circuit board. Put this switch in the set-up configuration at right while inputting the initial control
parameters.
SW201 Set-up Configuration
1 OFF Control Mode
2 OFF Normal/Reverse Output
3 OFF Input Shift
4 OFF Temperature Sensor
Standard
5 ON Scale Indication
6 ON PID Constant Indication