0

Out of 0 Ratings

Owner's of the Abbingdon Music Research Speaker System Reference Class Proffessional Monitor gave it a score of 0 out of 5. Here's how the scores stacked up:
  • Reliability

    0 out of 5
  • Durability

    0 out of 5
  • Maintenance

    0 out of 5
  • Performance

    0 out of 5
  • Ease of Use

    0 out of 5
of 53
 
23
Section 7 - Troubleshooting
Figure 7.1 Troubleshooting Guide
Symptom Possible cause Solution
No sound • incorrect audio cable connections • connect the cables correctly
• incorrect amplifier operation make sure that the input selector on the amplifier is set to
the desired source
Sound with no bass • check speaker connectors are not • check polarity using the AMR test CD and correct if
and generally strange connected with wrong polarity required
Sound is too bright or • Incorrect placement of speaker • Place speaker with high frequency driver upright and at /
dull ear hight, pointing at the listening position
• Incorrect adjustment of HF Level • Adjust HF level as per Appendix A
Bass is too full or lean • Incorrect placement of speaker • Place speaker correctly as per Section 2
• Incorrect use of port inserts • Add (if too full bass) or remove (if too lean bass) port
inserts as required
Other problems • go to the Contents section and re-trace the procedure
or contact your nearest AMR distributor/dealer