0.2

Out of 1 Ratings

Owner's of the 3M Carbon Monoxide Alarm MACURCO gave it a score of 0.2 out of 5. Here's how the scores stacked up:
  • Reliability

    0 out of 5
  • Durability

    0 out of 5
  • Maintenance

    0 out of 5
  • Performance

    1.0 out of 5
  • Ease of Use

    0 out of 5
of 2
 
Each person installing or using this equipment must read and understand the
information in these User Instructions before use. Installation of this equipment by
untrained or unqualified persons, or use that is not in accordance with these User
Instructions may adversely affect product performance and result in sickness or
death. For proper use see User Instructions or call 3M in U.S.A., 1-800-243-4630.
In Canada, call Technical Service at 1-800-267-4414.
The GD-2A is an electronic detector of combustible gases. The GD-2A is designed
for connection to UL Listed Fire Alarm/Burglary Control Panels. This combustible
gas detector has been evaluated by UL for methane (natural) and propane (LP) gas.
It is NOT designed to detect smoke, fire or carbon monoxide. Once the GD-2A is
operational (ARMED) the green light will be on continuously. If gas is detected the red
LED (ALARM) turns on and the alarm relay activates to indicate the alarm condition at
the control panel. In the configuration, as shipped from the factory, the GD-2A is self-
restoring meaning that when the air clears of gas, the red light turns off and the relay
switches to its normal state.
If you suspect a gas leak, alert others and have everyone leave immediately.
Do not light a match. Do not turn lights on or off. Do not use any electrical
switches, including a garage door opener. Do not use the telephone,
including cell phones. The electrical current in a phone, light or electric
switch is enough to spark an explosion.
Go outside to a safe place away from the suspect area and only then call
the gas company for help or in an emergency call 911.
Stay away from your home until someone in authority tells you it is safe to
return.
GENERAL SAFETY INFORMATION
INTENDED USE
The GD-2A is a low voltage (12-24 VAC or VDC) electronic detector of combustible,
heating type gases. The GD-2A is designed for connection to UL Listed Fire Alarm/
Burglary Control Panels. NOTE: Any time the words “Control Panel” or “Alarm Panel”
or “Alarm Control Panel” are used in these instructions, they refer to a UL Listed
Fire Alarm/Burglary Control Panel. Alarm control panels that work on 12 or 24 VDC
can provide battery backup to the GD-2A detectors. This combustible gas detector
has been evaluated by UL for methane (natural gas) and propane (LP) gas. It is NOT
designed to detect smoke, fire or carbon monoxide.
LIST OF WARNINGS AND CAUTIONS
Each person using this equipment must read and understand the
information in these User Instructions before use. Use of this equipment
by untrained or unqualified persons, or use that is not in accordance with
these User Instructions, may adversely affect product performance and
result in sickness or death.
Use only for monitoring the gas which the sensor and detector are
designed to monitor. Failure to do so may result in exposures to gases not
detectable and cause sickness or death. For proper use, see supervisor
or User Instructions, or call 3M in U.S.A., 1-800-243-4630. In Canada, call
Technical Service at 1-800-267-4414.
GD-2A may not function effectively below 32ºF (0ºC) or above
120ºF (50ºC). Using the detector outside of this temperature range may
adversely affect product performance and result in sickness or death.
This detector helps monitor for the presence and concentration level of
certain specified airborne gases. Misuse may produce an inaccurate reading,
which means that higher levels of the gas being monitored may be present
and could result in overexposure and cause sickness or death. For proper
use, see supervisor or User Instructions, or call 3M in U.S.A.,
1-800-243-4630. In Canada, call Technical Service at 1-800-267-4414.
The GD-2A is not designed to measure compliance with Occupational
Safety and Health Administration (OSHA) commercial or industrial standards.
When the unit is powered up it performs a self-test during which the
green LED light will blink for a period of one and one half to two minutes.
Afterward, the green LED light will turn on continuously to indicate the unit
is in normal operation (ARMED). If the self-test fails or the green LED light
does not turn on continuously do not use. Failure to do so may adversely
affect product performance and result in sickness or death.
Immediately exit the environment if there is an alarm condition on the
detector. Failure to do so may result in sickness or death.
This detector will only indicate the presence of combustible gas at the
sensor. Combustible gas may be present in other areas. Accommodation
spaces should be well ventilated when household cleaning supplies or
similar contaminants are used.
Do not cover or obstruct visual alarm LED. Doing so may adversely affect
product performance and result in sickness or death.
Do not disassemble unit or attempt to repair or modify any component
of this detector. This detector contains no user serviceable parts, and
substitution of components may adversely affect product performance and
result in sickness or death.
CAUTION
Avoid the use of harsh cleaning materials, abrasives and other organic solvents.
Such materials may permanently scratch the surfaces, damage the sensor,
labels, or instrument housing.
If you have any doubts about the applicability of the equipment to your job
situation, consult an industrial hygienist or call 3M at 1-800-243-4630. In
Canada, call Technical Service at 1-800-267-4414.
3
Macurco
Combustible Gas Detector GD-2
User Instructions for the 3M Macurco™ Combustible Gas Detector GD-2
Important: These User Instructions are to be provided to the homeowner/end
user upon product installation.
3M Occupational Health and
Environmental Safety Division
3M Center, Building 0235-02-W-70
St. Paul, MN 55144-1000
Printed in U.S.A.
3M and Macurco are trademarks of 3M.
© 2010 3M Company. All rights reserved.
98-0060-0162-6/2
34-8704-8986-0
W WARNING
W WARNING
USE INSTRUCTIONS AND LIMITATIONS
Each person using this equipment must read and understand the information
in these User Instructions before use. Use of this equipment by untrained
or unqualified persons, or use that is not in accordance with these User
Instructions, may adversely affect product performance and result in
sickness or death.
USE FOR
The GD-2A is an electronic detector of combustible, heating type gases (natural gas
and propane), designed for connection to alarm control panels. It can operate on 12
to 24 VDC power from standby or interruptible panel power, or be powered separately.
The GD-2A is intended for installation in buildings in non-hazardous locations such as
residences, retail stores, office buildings, and institutional buildings.
Use only for monitoring the gas which the sensor and detector are designed
to monitor. Failure to do so may result in exposures to gases not detectable
and cause sickness or death. For proper use, see supervisor or User
Instructions, or call 3M in U.S.A., 1-800-243-4630. In Canada, call Technical
Service at 1-800-267-4414.
DO NOT USE FOR
The GD-2A is NOT intended for use in industrial applications such as refineries,
chemical plants, etc. The GD-2A does NOT detect carbon monoxide. Do NOT mount
the GD-2A in a corner. The GD-2A is designed for connection to UL Listed Fire Alarm/
Burglary Control Panels. Do not connect the GD-2A to Fire Alarm Circuits, or Burglar
Alarm or other signals. The Alarm Control Panel must be dedicated to gas detection or
have alarm devices that provide a distinctive alarm for gas detection. Do NOT mount
the GD-2A in kitchens or bathrooms - alcohols, ammonia, cleaning solvents, paint
thinner, gasoline vapors, and aerosol propellants (aerosol cans such as hair spray
usually contain a combustible gas) may cause nuisance alarms.
GD-2A may not function effectively below 32ºF (0°C) or above 120ºF (50°C).
Using the detector outside of this temperature range may adversely affect
product performance and result in sickness or death.
GENERAL DESCRIPTION
The GD-2A is a low voltage (12-24 VAC or VDC) electronic detector of combustible,
heating type gases, that has been evaluated by UL for methane (natural gas) and
propane (LP) gas. The GD-2A is designed for connection to UL Listed Fire Alarm/
Burglary Control Panels. The GD-2A has a SPDT Alarm relay, for connection to control
panels or other devices. The GD-2A does NOT detect carbon monoxide. The GD-2A
does not have an internal audible sounder.
FEATURES
LISTED TO UL STANDARD 2075 FOR THE STANDARD FOR SAFETY FOR GAS AND
VAPOR DETECTOR AND SENSORS
SENSITIVITY TESTED BASED ON UL 1484 STANDARD FOR RESIDENTIAL GAS
DETECTORS
DETECTS HEATING GASES: PROPANE (LP), NATURAL GAS (METHANE),
SPDT ALARM AND N.C. TROUBLE RELAYS
CAN BE SELF-RESTORING OR LATCHING
ELECTRONIC SENSORS: NO MAINTENANCE OR RECALIBRATION
TEMPERATURE COMPENSATED
SIMPLE INSTALLATION AND OPERATION
SUPERVISED SENSOR
W WARNING
W WARNING
SPECIFICATIONS
SIZE: 4 1/2 X 5 X 1 5/8 inches
SHIPPING WEIGHT: 0.54 pound
VOLTAGE: 12 to 24 VAC or VDC
CURRENT (non-alarm): 45 mA @ 12 VDC, 22 mA @ 24 VDC, 65 mA
@ 12 VAC, 45 mA @ 24 VAC
CURRENT (in alarm): 70 mA @ 12 VDC, 35 mA @ 24 VDC, 100 mA
@ 12 VAC, 65 mA @ 24 VAC
COLOR: White
SENSOR MAINTENANCE: Not required
ALARM RELAY: SPDT, 0.125 AMPS, 40V, 3VA
TROUBLE RELAY: SPST (NC), 0.250 AMPS, 40V, 10VA
OPERATING TEMPERATURE RANGE: 32°F to 120°F (0°C to 50°C)
ALARM SET POINT: Per UL 1484 (25% LEL)
INSTALLATION AND OPERATING INSTRUCTIONS
The following instructions are intended to serve as a guideline for the use of the
3M™ Macurco™ GD-2A Combustible Gas Detector. It is not to be considered
all-inclusive, nor is it intended to replace the policy and procedures for each facility.
This detector helps monitor for the presence and concentration level of certain
specified airborne gases. Misuse may produce an inaccurate reading, which
means that higher levels of the gas being monitored may be present and
could result in overexposure and cause sickness or death. For proper use,
see supervisor or User Instructions, or call 3M in U.S.A., 1-800-243-4630. In
Canada, call Technical Service at 1-800-267-4414.
LOCATION
A GD-2A is usually located in each room (except kitchens or bathrooms) where there
are gas appliances or through which gas pipes pass. Do NOT mount the GD-2A in
a corner. Do NOT mount the GD-2A in kitchens or bathrooms - alcohols, ammonia,
cleaning solvents, paint thinner, gasoline vapors, and aerosol propellants (aerosol
cans such as hair spray usually contain a combustible gas) may cause alarms. Do
NOT mount the GD-2A where the normal ambient temperature is below 32°F (0°C) or
exceeds 120°F (50°C).
This product is intended for use in ordinary indoor locations of family
living units and office workspaces. The GD-2A is not designed to measure
compliance with Occupational Safety and Health Administration (OSHA)
commercial or industrial standards.
INSTALLATION
1. If the gas used is natural gas (methane) mount the GD-2A on a wall about one
foot down from the ceiling. If the gas used is propane (LP), mount the GD-2A on
a wall or column one foot above the floor. Use the same spacing as for smoke
detectors-30 foot centers, 900 square feet per detector.
2. The three part plastic case allows the GD-2A to be either surface mounted or
installed over a four-inch square or double gang electrical box, providing a near
flush mount. The GD-2A snap-on front cover will need to be removed before
installation. To remove it, lightly pry the front cover off of the mounting plate
(middle section) with a coin or flat screwdriver inserted into the vent at the
bottom. The cover will snap off exposing the electronics and mounting plate.
3. For flush mount, remove the 2 screws and rear cover from the mounting plate
and use the appropriate hole pattern for installation. The four holes toward the
center of the mounting plate match the hole pattern of a double gang electrical
box. The four holes near the corners match the pattern of a four-inch square
box. Mount the GD-2A so the “TOP” marked side of the mounting plate is at the
highest side. Snap the front cover back on when finished, making sure that the
lights line up with the access holes.
W WARNING
W WARNING
W WARNING